How to find whether a volume can be created in a DASD or not

 
Post new topic   Reply to topic    IBMMAINFRAMES.com Support Forums -> SMS & VSAM
Author Message
jerryragland

New User


Joined: 14 Jun 2005
Posts: 3

PostPosted: Wed Jun 15, 2005 4:51 pm    Post subject: How to find whether a volume can be created in a DASD or not
Reply with quote

Hi,

I have to initialize a new volume but I cant do it. I dont know why ?
I think due the non availability of physical storage I am not able to create a volume. can any one tell me how to find whether a volume can be created in a DASD or not.

regards,
Jerry Ragland.
Back to top
View user's profile Send private message
References
Karim

New User


Joined: 14 Jun 2005
Posts: 1
Location: Algeria

PostPosted: Wed Jun 15, 2005 8:06 pm    Post subject:
Reply with quote

What is the architecture of the mainframe and what is the operating system
Back to top
View user's profile Send private message
sharan Siva

New User


Joined: 28 Jun 2005
Posts: 5

PostPosted: Wed Jun 29, 2005 4:32 pm    Post subject:
Reply with quote

hi,

1.Check the do you have proper authority.

2.But you didn't provide more information, Did you volume is online.

3.check the control unit status that is online or not.

Thanks,
Sharan Siva.
Back to top
View user's profile Send private message
Gerald Kaiser

New User


Joined: 29 Jun 2005
Posts: 2

PostPosted: Wed Jun 29, 2005 4:48 pm    Post subject: Re: How to find whether a volume can be created in a DASD or
Reply with quote

Hi,
a) what do you mean by "non availability of physical storage" ?
b) which program do you use?
c) what error msg do you get?
Base info:
1) The pyhsical box must be installed
2) it must be connected via some cahnnel path to the LPAR you are running your program on.
3) The engineer must have defined the DASD-drives in the physical box, normally done after consultation with system-progs or storage-mngmt.
4) the DASD-device you want to init should be OFFLINE
5) when using ICKDSF on a newly installed box then VERIFY must not be coded, if the box was in use and you want to re-init, then you should favor using VERIFY
6) You must be RACF-authorized to access the volume/unit-address, ask your RACF-specialist about the required authorizations.
Hope this helps,