| Author |
Message |
Paul1983
New User
Joined: 08 Jul 2008 Posts: 24 Location: bangy
|
|
|
|
When I'm making some changes to an existing panel, its giving RC=20 in the DISPLAY PANEL section. Could you please tell why?
Regards,
Paul |
|
| Back to top |
|
 |
References
|
Posted: Wed Jul 09, 2008 2:46 pm Post subject: Re: RC=20 in DISPLAY PANEL |
 |
|
|
 |
ofer71
Global Moderator
Joined: 27 Dec 2005 Posts: 1862 Location: Israel
|
|
|
|
Try to display ZERRLM & ZERRSM. It will give you the exact reason.
O. |
|
| Back to top |
|
 |
expat
Global Moderator
Joined: 14 Mar 2007 Posts: 2817 Location: Brussels once more ...
|
|
|
|
You could also use the ISPF panel trace facility
| Code: |
"ISPEXEC ISPDPTRC PANEL(Name)"
"ISPEXEC DISPLAY PANEL(Name)"
"ISPEXEC ISPDPTRC VIEW"
|
|
|
| Back to top |
|
 |
ofer71
Global Moderator
Joined: 27 Dec 2005 Posts: 1862 Location: Israel
|
|
|
|
This is a chance to thank Mr. Nadel - Great job with ISPDPTRC. I liked it!!!
O. |
|
| Back to top |
|
 |
expat
Global Moderator
Joined: 14 Mar 2007 Posts: 2817 Location: Brussels once more ...
|
|
|
|
| Well, it has certainly dug (or should I say Doug ?) me out a few times so far, and no doubt a few more in the future |
|
| Back to top |
|
 |
Paul1983
New User
Joined: 08 Jul 2008 Posts: 24 Location: bangy
|
|
|
|
Hi,
After displaying ZERRLM & ZERRSM, I came to know the reason for the abend.Thanks for helping in resolving this
Regards,
Paul |
|
| Back to top |
|
 |
Moved: Wed Jul 09, 2008 5:11 pm by superk From CLIST & REXX to TSO/ISPF |
|
|