| Author |
Message |
Ed VanBebber
New User
Joined: 05 Jan 2008 Posts: 12 Location: Sacramento, Ca
|
|
|
|
I'm having problems diagnosing this abend. Job is intermittently bombing with the following:
CEE3250C The system or user abend U1188 R=05896596 was issued.
From compile unit FIS302 at entry point FIS302 at statement 3755 at compile unit offset +0000242E at entry
offset +0000242E at address 2B2032A6.
Any ideas?
Thanks |
|
| Back to top |
|
 |
References
|
|
 |
dick scherrer
Global Moderator
Joined: 23 Nov 2006 Posts: 9211 Location: 221 B Baker St
|
|
|
|
Hello,
Suggest you post considerably more info about the problem process. . .
What does the code do? What is at the statement mentioned in the abend? What do the abended runs have in common? Is this code used in multiple processes and do all of them sometimes abend? |
|
| Back to top |
|
 |
Ed VanBebber
New User
Joined: 05 Jan 2008 Posts: 12 Location: Sacramento, Ca
|
|
|
|
Thanks Dick Scherrer. The customer is not available for more info but job occasionally bombs in step15 and is using the sort work files from step5.
//STEP05 EXEC PGM=&FIS100,TIME=30,COND=(0,NE)
//STEPLIB DD DSN=TZ.Y2K.PRODLIB,DISP=SHR
//Y2KWIN DD DSN=TRUCAT02.TZ.Y2K.CENTURY.WINDOW,DISP=SHR *READ*
//FISADD DD DSN=TZ.Y2K.APSCNTRL(FISSRTA),DISP=SHR
//FISACNTL DD DSN=TZ.Y2K.APSCNTRL(FIS41AA),DISP=SHR
//SORTWK01 DD UNIT=(SORTDA,4),SPACE=(CYL,(300,300)),DISP=(,PASS)
//SORTWK02 DD UNIT=(SORTDA,4),SPACE=(CYL,(300,300)),DISP=(,PASS)
//SORTWK03 DD UNIT=(SORTDA,4),SPACE=(CYL,(300,300)),DISP=(,PASS)
//OC DD DSN=TRUCAT02.TR.FIS.PROD1.OC,DISP=SHR
//SM DD DSN=TRUCAT02.TR.FIS.PROD1.SM,DISP=SHR
//VE DD DSN=TRUCAT02.TR.FIS.PROD1.VE,DISP=SHR
//STEP15 EXEC PGM=&FIS302,TIME=45,COND=(0,NE)
//STEPLIB DD DSN=TZ.Y2K.PRODLIB,DISP=SHR
//Y2KWIN DD DSN=TRUCAT02.TZ.Y2K.CENTURY.WINDOW,DISP=SHR *READ*
//FISADD DD DSN=TZ.Y2K.APSCNTRL(FISSRTA),DISP=SHR
//FISACNTL DD DSN=TZ.Y2K.APSCNTRL(FIS41AC),DISP=SHR
//$ORTPARM DD DSN=TZ.Y2K.APSCNTRL(FIS41A15),DISP=SHR
//SORTWK01 DD DSN=*.STEP08.SORTWK01,DISP=(OLD,PASS)
//SORTWK02 DD DSN=*.STEP08.SORTWK02,DISP=(OLD,PASS)
//SORTWK03 DD DSN=*.STEP08.SORTWK03,DISP=(OLD,PASS)
//CNT DD DSN=TR.FIS.PROD1.RECONCIL(+1),DISP=(SHR,PASS)
//SM DD DSN=TRUCAT02.TR.FIS.PROD1.SM,DISP=SHR,AMP=('BUFNI=2') |
|
| Back to top |
|
 |
CICS Guy
Senior Member
Joined: 18 Jul 2007 Posts: 1229 Location: At my desk
|
|
|
|
Explanation: A system or user abend has occurred.
Programmer Response: Look in the messages and codes or system codes manual for the particular platform to resolve the system-described problem. |
|
| Back to top |
|
 |
Ed VanBebber
New User
Joined: 05 Jan 2008 Posts: 12 Location: Sacramento, Ca
|
|
|
|
| Thanks CICS Guy but qw was not very helpful |
|
| Back to top |
|
 |
CICS Guy
Senior Member
Joined: 18 Jul 2007 Posts: 1229 Location: At my desk
|
|
|
|
FWIW,
| a Google of U1188 wrote: |
I just wanted everyone to know what fantastic response I have been getting from IBM, EMC and Syncsort on this issue.
IBM and EMC are seeing a channel error and are working on this aspect. Syncsort did a fantastic job of helping to identify the direction of this error for me.
Second, out of this issue, Syncsort has recognized that the message
WER494I INPUT PHASE USED MIDAW
maybe produced with MIDAW is disabled. They are currently working on a fix. |
And why are even defining the sortworks? |
|
| Back to top |
|
 |
Ed VanBebber
New User
Joined: 05 Jan 2008 Posts: 12 Location: Sacramento, Ca
|
|
|
|
| That is great info CICS Guy....Thank you! |
|
| Back to top |
|
 |
dick scherrer
Global Moderator
Joined: 23 Nov 2006 Posts: 9211 Location: 221 B Baker St
|
|
|
|
You're welcome
There is an old IBM phrase that comes to mind. . .
"The results may be unpredictable. . .".
I suggest you remove the referbacks to the SORTWK datasets. Also seems kind of spooky to have a "+1" with disp=shr. . . |
|
| Back to top |
|
 |
Ed VanBebber
New User
Joined: 05 Jan 2008 Posts: 12 Location: Sacramento, Ca
|
|
|
|
| I will run those suggestions by the customer. Thanks again CICS Guy. |
|
| Back to top |
|
 |
|
|
|